Description
Overview
The EPRO CON021/915-080 is a high-precision eddy current signal converter designed for rotating machinery monitoring. It accurately measures shaft displacement, position, eccentricity, and speed/key signals. It is widely used in steam, gas, and hydro turbines, as well as compressors, pumps, and fans.
This model works with multiple eddy current probes, including PR6422, PR6423, PR6424, PR6425 (requires extended range converter), PR6426, and PR6453. It converts sensor signals into standardized analog outputs for integration with monitoring and protection systems. The CON021/915-080 is optimized for MMS 6000 and IMR 6000 rack systems and supports hot-swappable installation, ensuring continuous operation of critical rotating equipment.
Technical Specifications
| Parameter | Specification |
|---|---|
| Function | Eddy current signal converter for shaft displacement, position, eccentricity, and speed/key monitoring |
| Frequency Range | 0–20 kHz (-3 dB) |
| Rise Time | <15 μs for accurate dynamic measurement |
| Compatible Sensors | PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, PR6453 |
| Supply Voltage | -23V to -32V (Output -4V to -20V) -21V to -32V (Output -2V to -18V) |
| Output Signal | Standardized analog output (depending on configuration) |
| Operating Temperature | -30°C to +100°C (-22°F to +212°F) |
| Shock & Vibration | 5g @ 60 Hz @ 25°C |
| Protection Class | IP20 |
| Housing Material | LMgSi 0.5 F22 Aluminum Alloy |
| Weight | 120 g |
| Mounting | Rack-based installation (MMS 6000 / IMR 6000 compatible) |
| Connections | Self-locking LEMO plug or screw terminal options |
| Integration | Hot-swappable for rack systems |
Applications
-
Steam, gas, and hydro turbine monitoring
-
Rotating machinery: compressors, pumps, and fans
-
Process control and protection systems
FAQ
Q1: Which sensors are compatible with CON021/915-080?
A1: Compatible with PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, and PR6453.
Q2: Can this module be replaced while running?
A2: Yes, it supports hot-swappable installation in MMS 6000 and IMR 6000 racks.
Q3: What is the typical measurement range?
A3: Using PR6425 extended range, ±8.0 mm with ≤3% linearity error.
Q4: What is the operating temperature range?
A4: -30°C to +100°C, suitable for most industrial rotating machinery environments.
Features
Dobrodošli su nam veleprodajni nalozi i imamo minimalnu količinu narudžbine od samo jedne jedinice.
Na zahtev, možemo obezbediti svu potrebnu dokumentaciju, uključujući Sertifikate o poreklu/usaglašenosti i druge potrebne izvozničke dokumente.
Za artikle na lageru, cilj nam je da isporučimo u roku od 1-3 dana nakon potvrde uplate. Artikli sa navedenim rokovima isporuke biće isporučeni u skladu sa navedenim rasporedom.
Prihvatamo 100% T/T (telegrafski transfer) plaćanje pre slanja. Za artikle sa vremenom isporuke, zahteva se avans od 30%, dok se preostalih 70% plaća pre slanja. Za RMB transfere, molimo kontaktirajte nas ako imate agenta u Kini.
Нудимо стандардну једногодишњу гаранцију на све нове и оригиналне артикле. Ако вам је потребна продужена гаранција, молимо контактирајте нас за детаље о додатним трошковима.
Vaše zadovoljstvo nam je važno. Ako treba da vratite artikal, to mora biti urađeno u roku od 30 dana od datuma porudžbine. Proizvod mora biti neupotrebljen, neotvoren i u originalnom pakovanju sa svim uključenim dodacima. Povraćaj novca se obrađuje u roku od 5-7 radnih dana nakon što primimo vraćeni artikal. Molimo vas da imate na umu da troškovi dostave i povezani troškovi nisu povraćajni.