Description
Overview
The Honeywell FS-SICC-1011/L3 is a high-performance shielded interconnection cable designed for Safety Instrumented Systems (SIS), Distributed Control Systems (DCS), and fire alarm networks. Engineered for reliability, this cable ensures consistent signal integrity, electrical isolation, and robust protection in demanding industrial environments.
Technical Specifications
| Specification | Details |
|---|---|
| Cable Type | Shielded twisted-pair interconnection |
| Conductors | 9 copper conductors |
| Wire Gauge | 28 AWG |
| Shield | Braided for EMI/RFI protection |
| Voltage Rating | Up to 300 V |
| Conductor Resistance | 5.2 Ω/km at 20 °C |
| Insulation Resistance | ≥ 500 MΩ/km |
| Jacket Material | Flame-retardant PVC |
| Connector Type | D-sub connectors at each end |
| Standard Length | 3 m (9.8 ft), custom lengths available |
| Operating Temperature | -20 °C to +60 °C |
| Storage Temperature | -40 °C to +80 °C |
| Compliance | Honeywell SIS/DCS standards, NFPA fire safety requirements |
| Weight | 0.2 kg |
Key Features
-
Shielded design minimizes electromagnetic interference.
-
Flame-retardant jacket provides enhanced safety for fire alarm applications.
-
Electrical isolation ensures safe testing and commissioning of live loops.
-
Durable construction resists oils, chemicals, and mechanical stress.
-
Compatible with Honeywell controllers, I/O modules, and Field Termination Assemblies (FTA).
Applications
-
Safety Instrumented Systems (SIS): Reliable connection between safety controllers and field devices.
-
Distributed Control Systems (DCS): Stable interconnection for process automation networks.
-
Fire alarm systems: NFPA-compliant interconnection between panels and sensors.
-
Industrial automation: Oil & gas, chemical plants, and manufacturing environments requiring shielded cabling.
FAQ
Q: Can this cable be customized in length?
A: Yes, lengths beyond the standard 3 m can be configured upon request.
Q: Is the cable suitable for high-voltage applications?
A: It is rated up to 300 V; higher voltage applications require alternative specification cables.
Q: How does this differ from FS-SICC-1010 series cables?
A: The FS-SICC-1011/L3 provides enhanced EMI shielding and a flame-retardant jacket, making it more suitable for SIS and fire alarm systems.
Features
Dobrodošli su nam veleprodajni nalozi i imamo minimalnu količinu narudžbine od samo jedne jedinice.
Na zahtev, možemo obezbediti svu potrebnu dokumentaciju, uključujući Sertifikate o poreklu/usaglašenosti i druge potrebne izvozničke dokumente.
Za artikle na lageru, cilj nam je da isporučimo u roku od 1-3 dana nakon potvrde uplate. Artikli sa navedenim rokovima isporuke biće isporučeni u skladu sa navedenim rasporedom.
Prihvatamo 100% T/T (telegrafski transfer) plaćanje pre slanja. Za artikle sa vremenom isporuke, zahteva se avans od 30%, dok se preostalih 70% plaća pre slanja. Za RMB transfere, molimo kontaktirajte nas ako imate agenta u Kini.
Нудимо стандардну једногодишњу гаранцију на све нове и оригиналне артикле. Ако вам је потребна продужена гаранција, молимо контактирајте нас за детаље о додатним трошковима.
Vaše zadovoljstvo nam je važno. Ako treba da vratite artikal, to mora biti urađeno u roku od 30 dana od datuma porudžbine. Proizvod mora biti neupotrebljen, neotvoren i u originalnom pakovanju sa svim uključenim dodacima. Povraćaj novca se obrađuje u roku od 5-7 radnih dana nakon što primimo vraćeni artikal. Molimo vas da imate na umu da troškovi dostave i povezani troškovi nisu povraćajni.